Error Code
Error Code Lookup
If your unit displays an error code, click below to find the cause and solution:
Check Error Codes
| Display | Cause | Solution |
| E0 | Error of water temperature sensor: 1. Connector is loose or of poor contact. 2. Open circuit or short circuit of sensors or the sensors touch the housing. 3. Circuit board malfunction of main controller. |
1. Secure connection, or replace the poor connector. 2. Replace the temperature sensor. 3. Replace the main circuit board (repair the relevant circuit). |
| E1 | Ignition failure, flame out failure: 1. Lines for ignition and flame detection falloff or contact poorly. 2. Gas valve closed. 3. Ignition is unsuccessful. |
1. Connect the relevant components well and exclude the defective components. 2. Open the gas valve. 3. Check if the gas pressure is too high or too small, or no gas supply, make sure the gas supply is normal. |
| E2 | False fire failure: Flame signal detected before ignition 1. Flame sensor failure. 2. Controller failure. |
1. Replace the sensor pin. 2. Replace the controller. |
| E3 | Thermostat failure: Prolonged high-load operation, low water pressure or high gas pressure will cause the water heater to malfunction and overheat. |
Test the air supply circuit, rectify faults to restore normal pressure, then raise water pressure. Reduce hot water temperature slightly if pressure is non-adjustable. |
| E4 | Thermostat failure: 1. Loose connectors or poor contact. 2. Sensor open/short circuit. 3. The main controller is faulty. |
1. Insert the connector, or replace the bad connector. 2. Replace the sensor. 3. Replace the main control board (repair the related circuit). |
| E5 | Fan, wind- pressure failure: 1. Insufficient power supply causes low fan speed. 2. With debris in the fan, making it block and stop running. 3. Power supply control module of fan is damaged. 4. Connector is loose or of poor contact. |
1. Check the voltage. 2. Remove debris, and eliminate the blockage failure. 3. Replace the burnt-out components (power board, main control panel). 4. Insert the connector well, or replace the poor connector. |
| E6 | Overheating protection. | Normal protection function. |
| E7 | Valve failure: 1. Connecting wires are loose, damaged or of poor contact. 2. Solenoid valve stuck. |
1. Insert the connecting wires well and replace the poor components. 2. Remove the solenoid valve and clean it |
| E8 | Fan speed is over limit: The flue is blocking. |
Remove debris, and eliminate the blockage failure. |
| En | Timing shutdown. | Normal safety protection function, restart the appliance. |
| Ec | Communication failure: 1. Poor communication line connection. 2. The remote controller is damaged. 3. The controller is damaged. |
1. Reconnect the lines. 2. Replace the remote controller. 3. Replace the controller. |
| EE | Internal failure of the control system: 1. Voltage too high or too low. 2. Insufficient power supply. 3. Current is less than 5A. |
1. Replace the controller. 2. Replace with a suitable power supply. 3. Replace with a DC power supply rated 5A–10A. |
| Ed | Anti-freezing system active in cold weather. |
System is firing the burner to prevent freezing of any water in the system. Burners will run until safe warmer temperature is reached. Normal operations. |
Tip: Most error codes are related to gas, water, or power supply and can be resolved quickly.